Description
GreaseShield® GS1850-PF Product Overview
Approvals
- ASME A112.14.3-2000 – Testing of Grease Interceptors
- ASME A112.14.4-2001 – Grease Removal Devices
- CSA B481.0-2012 – Testing of Grease Interceptors
- CSA B481.1-2012 – Testing and Rating of Grease Interceptors using Lard
- CSA B481.5-2012 – Testing and Rating of Grease Interceptors Equipped with a Grease Removal Device
- PDI G 101
- UL Approved (File No: E361705)
- Machinery Directive 2006/42/EC and EMC Directive 2004/108/EC
Flow Rates
- Passive PDI: 7 GPM / 26.5 L/m
- Pro Active: 1.8 L/S
Application
Designed for use with:
- Pot Wash & Pre-Rinse Double Bowl Sinks
- Hood Dishwashers
Note: Do not exceed rated flow capacities.
Functions & Features
- PreFilter
- Recirculation – Water surface spray enhances FOG removal and cleans outlet weir area (linked to cleaning LED).
- Anti-Flood Pump – Maintains normal water level with a recalibration feature.
- Water Connection – WRAS-approved (or equivalent) water solenoid.
- CIP Bar
- Pressure Switch & Air Sensor
Parts Supplied as Standard
- Vortex Flow Controller (VFC) – Fitted as standard
- FlexiPlumb
- 54mm 90° bend (0635P02-54)
- 34mm 90° bend (0635P02-34)
- Blanking Cap (0635P10)
- Key (0509P86)
- ¾” Braided Hose for Hot Water (0214P15)
- Plumbing Pack (see note below)
Default Program (V5.4, V1.4)
- Start: 07:00 AM
- Stop: 02:30 AM
- FOG Roller: Pulses 5 min on / 5 min off
- Anti-Flood & Recalibration Cycle: Activates when water intake is triggered, FOG roller is inhibited
- Mains Lead: Configured per country
Installation Kit
- Stainless Steel 304 hygiene & service access adjustable stand (essential for installation)
- IP56 Socket
- Best Practice Management and Do’s and Don’ts – Laminated for on-site display
- Daily Maintenance Logbook – 12-month duration
- Sampling Point
Labelling
- Voltage per country
- Flow rate per country
- Labels per country
- Labels per distributor
Power Consumption
- Average Power Consumption per Hour: 23.0 Watts
Additional Notes
- All FlexiPlumb supplied with jubilee clip fasteners
- VFC = Vortex Flow Controller
Country-Specific Installations
UK Installs
- AQUACHECK 15DN (WRAS Certified) or equivalent double check valve required on all GreaseShield® (STD Range Models) to comply with WRAS backflow prevention.
EU Specifications
- Voltage: 240V
- Frequency: 50Hz
- Current: 0.49A
US Specifications
- Voltage: 120V
- Frequency: 60Hz
- Current: 0.98A


Reviews